Fire barrier promo
  • Introduction
  • Reflex
  • Multiflex
  • FB-97
  • UL Listings
  • Installation

only feild testable

Because fire is an ever-present danger, the chimney effect at unprotected expansion joints may actually advance its spread. For this reason, C/S has developed three fire barrier systems designed to be used with any of our expansion joint assemblies. All systems have been tested at Underwriters Laboratories and are UL® Classified and Labeled.

explo Home

reflex for joints

Reflex is an innovative and cost effective new fire barrier system consisting of a compressible block of insulation housed in continuous stainless steel foil. Installation is as simple and economic as it gets!

multiflex

Multiflex is a patented system of insulation layers encapsulated in stainless steel mesh. The mesh keeps the insulation in place and allows up to 50% lateral shear, a unique feature in the industry. Multiflex is supplied in standard 10’ lengths.

fire barrier

Fb-97

FB-97 utilizes multiple layers of ceramic insulation separated by air space. The barriers’ insulation design allows FB-97 to maintain the required temperature limit for 2 hours while open to 72 inches. FB-97 is available with optional 100% lateral shear capability for 4-way movement.

fire barrier

ul listings

C/S tests all of its fire barriers at Underwriters Laboratories (UL) because they represent the most stringent and universally accepted testing authority. For complete test results & UL listings for all C/S Fire Barriers click below.
UL Listings

firebarrier
Reflex Installation
Reflex Floor (1"-3")
Reflex Floor (4")
Reflex wall (1"-4")
Multiflex Installation
Multiflex (1"-6")
Multiflex (7"-20")
FB-97 Installation
FB-97 Floor (7"-24")
FB-97 Floor (25"-36")
FB-97 Wall (7"-20")
FB-97 Chase Wall (7"-28")